Burak Ak

Burak Ak

Mersin University Faculty of Dentistry, Mersin, Turkey

Profile ID RP-000-0312 Joined 2023-01-16 2 articles

Articles(2)

Authors: Burak Ak, Emre Gürkan Eroglu

DOI: 10.18231/j.ijpi.2022.035  

Volume7

Issue4

Pages161-175

Abstract

Dentists are at risk of noise-induced hearing loss (NIHL). Dental treatment equipment has high-intensity noise levels. Occupational noise levels of multi-unit dental clinic are higher than private clinic and are at further increased risk of NIHL. This study aims to develop a noise-reducing appointment system in multi-unit dental clinics using treatment duration and steps noisemap. Restorative, periodontal, and prosthetic dental procedure noise levels were measured in a multi-unit dental clinic. A procedure noise map was created by measuring the amount of noise in the treatment time interval and the silent treatment period. The appointment algorithm was created according to this noise map. Control and 7 test simulation appointment algorithms were tested. The control group was simulated in six units simultaneously with conventional hour-based appointment algorithm. Test groups were simulated according to the appointment algorithm based on the treatment steps noisemap. Six-unit dental clinic was simulated under the dBmap system. While 2 of the 6 units in the test groups are in noise producing treatment steps, the other 4 seats are planned to operate without noise. According to treatment steps noisemap, test groups operated two-unit simultaneously at different timings. The distribution of noise producing units in the clinic was simulated in 7 groups (T1-T7). The mean noise measurements in all tested groups were significantly lower than in the control group. Periodontal treatment mean occupational noise level (68 dB) was higher than restorative (61 dB) and prosthetic treatment (59 dB). Control room mean occupational noise measurement was 68,54 dB, and test groups mean occupational noise measurements were between 57,19 –63,98 dB. The difference between control and tested groups was significantly different(p=0,0009). Occupational noise was significantly reduced with the noise reduction-based appointment method. Further studies are needed with different treatment procedures and validation studies in clinical settings. Keywords: Occupational noise, Appointment, Periodontal, Prosthetic, Restorative, Treatment, Dental clinic, Noise­ map

Open full article page

Authors: Burak AK*

DOI: 10.18231/j.jooo.2023.007  

Volume9

Issue1

Pages29-38

Abstract

The surgical procedure that lessens edema formation after frenectomy surgery is important.Re-epithelialization with lasers occurs differently from conventional surgery, and this can affect the salivary EGF level. The aim of this study was to determine edema caused by frenectomy surgery and compare the amount of EGF in saliva. Conventional and 810 nm diode laser surgery performed with thirty-four patients. Laser parameters were 400 µm fiber with 2.5 W output energy, in continuous mode.3D face scan data was obtained with a Planmeca Proface Mid device and analyzed with the 3D metrology method using the CloudCompare V2 software. Cephalometric analysis was performed using 2D profile photographs with Geogebra software. Edema measurements were repeated on day 1 (T1), day 3 (T2) and day 14 (T3). All saliva samples were collected at T1 and T3 and salivary EGF concentration was determined using the ELISA method. In conventional surgery, a significant difference was found between ?T2-T1 and ?T3-T1 in 3D metrology measurements (p=0.0046). In 2D cephalometric measurements there was significant differences in Angle A T2-T1 vs. Angle A T3-T1 (p=0,0014) and vs. Angle B T2-T1 (p=0,0017) and vs. Angle B T3-T1 (p=0,0087) in conventional surgery. There were no significant changes in edema measurements of laser surgery. The laser frenectomy does not produce edema significantly (p=0,1232). There were no significant changes between groups in salivary EGF measurements (p>0.999). The 810 nm laser surgery produced less edema than conventional surgery. The 810 nm diode laser does not significantly affect salivary EGF.   Keywords: Laser, Conventional, Frenectomy, Edema, Face scan, Cephalometry, EGF, 810 nm diode.

Open full article page

No matching articles

Try another word from the title, author or DOI.