Hemant Sharma

Hemant Sharma

J.L.N. Medical College and Hospital, Ajmer, Rajasthan, India

Profile ID RP-000-1463 Joined 2023-01-17 2 articles

Articles(2)

Authors: Hemant Sharma*, Sanjeev K Nainiwal, Akshay Sarraf, Rakesh Porwal, Vijaya Sharma

DOI: 10.18231/j.ijceo.2022.016  

Volume8

Issue1

Pages85-88

Abstract

Purpose: Checking of intraocular pressure (IOP) is one of the basic investigations in a general ophthalmology work up. In this study we attempted to compare the IOP readings obtained by Goldmann applanation tonometer and Schiotz indentation tonometer in glaucomatous and normal individuals attending general ophthalmology OPD in a tertiary care centre in Central Rajasthan. Materials and Methods: It is a case series study in which IOP was checked in patients using two tonometers. Statistical analysis was done to evaluate the agreement between instruments. Result: In this study, when measured with Goldmann applanation tonometer (GAT), it was found that the mean IOP of both right and left eye in group A (Glaucomatous subjects) (24.19±12.94 and 23.34±13.73 respectively) was significantly higher than mean IOP of both right and left eye in group B(non glaucomatous subjects) (15.06±2.49 and 15.12±2.38 respectively). Likewise, when measured with Shiotz tonometer (ST), mean IOP of both right and left eye in group A (26.05±11.93 and 24.65±12.28 respectively) were very significantly higher in comparison to group B (16.79±2.64 and 16.85±2.47 respectively). Conclusion: The mean pressures obtained by the Schiotz tonometer were higher than the mean Goldmann pressures which indicate that the Schiotz tonometer tends to read higher than the Goldmann tonometer.   Keywords: Glaucoma, Tonometry, Schiotz tonometer, Goldmann applanation tonometer (GAT).

Open full article page

Authors: Hemant Sharma, Sanjeev K Nainiwal, Akshay Sarraf, Rakesh Porwal, Vijaya Sharma

DOI: 10.18231/j.ijceo.2020.069  

Volume6

Issue3

Pages315-323

Abstract

According to the World Health Organization, glaucoma is the leading cause of irreversible blindness worldwide. Although intraocular pressure (IOP) is not considered any more to be a defining feature of the disease, its lowering remains the only treatment option for glaucoma. Therefore accurate and precise measurement of IOP is the cornerstone of glaucoma. Intraocular pressure is a highly dynamic physiological parameter with individual circadian rhythms. The main limitation of current tonometry methods remains the static and mostly office-based nature of their measurements. Keywords: Glaucoma, Intraocular pressure (IOP), Tonometry.

Open full article page