Journal article

Flip-flop circulation: An unusual cause and case of neonatal desaturation

LGLalit Gupta LGLalit Gupta TJTarang Jain TJTarang Jain
Year0
Volume5
Issue4
Pages627-628

Abstract

Neonates are given anaesthesia for multiple surgeries, however coupling neonatal physiology with child physiology is a common error made. Circulation changes at birth from the foetal to adult type, but neonates are prone to revert to foetal circulation with disastrous effects. This phenomenon is known as flip flop or YoYo circulation. We report a case of a premature neonate, being operated for intestinal perforation, with Yo Yo circulation intraoperatively.

Keywords: Neonate anaesthesia, Flip flop circulation, Yo Yo circulation, Neonatal surgery, Desaturation, Hypoxia.