Breaking the code of guided implant surgery with an innovative blend of convenience & precision: A pilot study on accuracy of an ingenious 3d implant surgical guide

Authors : Ranjoy Hazra, Ayush Srivastava, Dinesh Kumar, Amit Khattak, V S Legha, Deepak Kalia, Kamal Verma

DOI : 10.18231/j.jdp.2022.006

Volume : 4

Issue : 1

Year : 2022

Page No : 25-30

Statement of Problem: The aim in our pilot research study is to evaluate accuracy of implant placed using guided surgery with an ingeniously developed guide, therefore the deviation between the virtual planning and the postoperative implant position has to be evaluated.
Materials and Methods: 7 patients were randomly selected from the Out Patient Department of our hospital and 10 implants were placed in them with the help of an indigenously developed 3D surgical guide. Pre-operative & Post-operative CBCT was compared in a software for the evaluation of precision. Site specific comparative evaluation was done in 4 parameters i.e., entry deviation, apex deviation, depth deviation in single plane and angulation between long axis of placed and planned implants.
Results: The results were tabulated and standard statistical analyses were done. Mean ± Standard deviation of entry deviation were 0.4 ± 0.29 mm., exit deviation 0.7 ± 0.33 mm., angulation deviation 3 ± 1.7 deg. And depth deviation 0.2 ± 0.13 mm. All the P values were < 0> Conclusion: This evidence backed ingeniously designed implant template reliably guides precise & predictable implant placement in each & every case thus promulgating the best care for all concept further with a vision for the future.


Keywords: Guided Implant surgery, 3D Implant Guide, Ingenious implant guide