Increasing the efficiency of the system by changing the capacitor method transmitter to the hydrostatic pressure method to measure the level of reservoirs (case study of Ramin power plant)

Authors : Mohammad Reza Ghodsi

DOI : 10.5281/ZENODO.11387950

Volume : 9

Issue : 2

Year : 2024

Page No : 100-114

The level Transmitter of Industrial Tanks, Which are Considered as the Main Equipment of Precision Instruments, always Suffer Wear and Tear and Inefficiency with the Passage of Time. Various Methods have been Provided to Increase the Accuracy, Stability of the Indicated Values and Increasing efficiency of the system Regarding Level Measurement, one of these Methods is Hydrostatic Pressure. The main Purpose of This Research is to Fully Describe the Installation and Commissioning Stages of the Hydrostatic Pressure Level Transmitter Located in the Ahvaz Ramin Power Plant, as Well as to Review and Study their Efficiency, Using Actual Operation Data, Which is for Confirmation and Validation. , the Results of This Research Were Compared with the Example of Capacitive Method. Increasing the Accuracy and Precision of Values, Not Depending on the Temperature of the Sensor, Reducing Failure and Lower Costs, Increasing the Safety of the System and Equipment, and Being Resistant to Turbulence and Loading Tanks, Simplicity and Ease of Installation, and the Ability to Display with High Resolution are Considered to be the Main Features of the Hydrostatic Pressure Level Transmitter.


Citation Data