Athiyamaan M S

Athiyamaan M S

Profile ID RP-000-3688 Joined 2023-01-20 2 articles
0Connections
8
Total Views
2
Total Publications
28
Publication Views

Articles(2)

Authors: Sharaschandra Shankar, Hepsiba Priyadarshini, Donald Fernandes, Athiyamaan M S, Sandesh Rao B, Sridhar C H

DOI: 10.18231/j.jdpo.2020.074

Volume5
Issue4
Pages381-385
Abstract

Background: Spleen being in close proximity to radiation field in patients of gastric and gastroesophageal carcinomas treated with radiotherapy will inadvertently receive a part of the dose. The purpose of this study was to determine the impact of radiation dose and fractional volume of irradiated spleen in the setting of chemoradiation therapy for gastric and gastroesophageal junctional cancers on haematologic toxicity. Materials and Methods: 40 patients with gastric and gastroesophageal junctional cancers who received concurrent chemoradiation were retrospectively analysed in the Department of Radiation oncology, Father Muller Medical College. Splenic dose-volume histogram (DVH) parameters were calculated as mean splenic dose (MSD) and percentage of splenic volume receiving 10 Gy (V10), 20 Gy (V20), 30 Gy (V30) and 40 Gy (V40) dose and correlated with clinical blood parameters.Mean, percentage, standard deviation and Student paired t-test were used to analyse the results. Results: All the patients experienced haematological toxicities, including 7 patients with grade 3 leukopenia and 3 had grade 4 leukopenia, 19 with grade 2 thrombocytopenia and 4 had grade 3 thrombocytopenia, 28 with both leukopenia and lymphopenia. Mean dose to the spleen was 32 Gy (range 27–37). Higher spleen V10-V40 was correlated with leukopenia, lymphopenia and thrombocytopenia. Conclusion: This dosimetric study demonstrates that splenic radiation was correlated with haematological toxicities, however role of chemotherapy as cause for toxicity could not be assessed as separate variable in this study. Future clinical correlational studies are needed to significantly determine the splenic dose contraints. Key Messages: Radiation therapy for gastric and gastroesophageal carcinoma leads to significant dose to spleen causing an impact in acute haematological toxicities. Keywords: Spleen irradiation, GI malignancy, Radiotherapy, Haematological toxicities.

Authors: M S Athiyamaan, C H Sridhar

DOI: 10.18231/j.ijpo.2020.124

Volume7
Issue4
Pages631-635
Abstract

Background: Interfraction variations occur due to tumour regression during cervical intarcavitary brachytherapy (ICR) requiring replanning with every fraction. This study aimed to determine the correlation of interfraction variations in positioning of applicator and its relationship with relative dosimetry if the dwell time and source positions of the plan of first fraction were applied to other subsequent fractions. Materials and Methods: This is a retrospective review of the orthogonal radiographs of cervical cancer patients treated from 2013 to 2016 in our institute, receiving ICR with the same dose prescription to point A using a tandem and two ovoids applicators. A hypothetical second and third plan were obtained by applying the same source positions and dwell time as in the first fraction plan. The dose delivered to point A, point B, cervical point, bladder point and rectal point were determined. The actual doses in the treated second and third fractions were compared with these hypothetical plans for any significant change in relative dosimetry. Statistical differences between groups were analysed using 2 tailed paired t test. Results: There was consistant increase in the doses to the point B, bladder point and rectal point in all the hypothetical plans with statistically significant difference observed for point B (p=0.001), rectal point (p=0.000) and bladder point(p=0.041). Conclusion: The conception of avoiding the replanning if similar interfraction conditions are achieved looks promising but the significant findings observed in this study warrants strongly to continue as per current recommendation of replanning with every fraction of brachytherapy. Keywords: Actual plan, High dose rate brachytherapy, Hypothetical plans, Interfraction variation, Replanning.

No matching articles

Try another word from the title, author or DOI.

Brief Bio

No bio added yet.

Affiliations

Nothing added yet.

Education

Nothing added yet.

Honors & Awards

Nothing added yet.

Society Memberships

Nothing added yet.

Expertise

Nothing added yet.

Specialty

Nothing added yet.

Other Online Pages

Followers(0)

Nobody here yet.

Following(0)

Nobody here yet.

2 Publications