Shreyasi Mallick

Shreyasi Mallick

Senior Resident

Kalinga Institute of Medical Sciences, Bhubaneswar

Profile ID RP-003-3613 Joined 2025-06-10 1 article
0Connections
7
Total Views
1
Total Publications
24
Publication Views

Articles(1)

Authors: Saswati Das, Shreyasi Mallick, Sujit Pradhan, Supriya Kar

DOI: 10.5005/jp-journals-10071-24871

Volume29
Issue1
Pages14-20
Abstract

Background: To evaluate the role of ultrasound (US) in the assessment of the airway and to determine whether US has the potential to serve as effective, noninvasive and less time-consuming method for the diagnosis of difficult intubation in ICU patients. Patients and methods: This cross-sectional study was carried in 152 critically ill patients who underwent intubation in the ICU from December 2022 to April 2024. Prior to intubation thyromental height (TMH) and hyomental distance ratio (HMD-R) was measured using a scale and distance from skin to hyoid bone (SHB) and distance from skin to thyrohyoid membrane (STM) was measured using a US. Direct laryngoscopy was performed using a Macintosh blade, and the Cormack–Lehane (CL) grade was noted without external laryngeal manipulation. The laryngoscopy was classified as easy (CL Grade I and II) or difficult (CL Grade III and IV). The number of attempts at intubation, need for alternative difficult intubation approaches or inability to secure the airway was also noted. Results: The incidence of difficult airway was 17.76%. The success rate for first-attempt intubation was 96.7%. Based on the receiver operating characteristic (ROC) curve analysis cut-off value of 1.97 cm [95% confidence interval (CI), 0.949–0.996, area under the curve (AUC), 0.972] for anterior soft tissue thickness from the skin to thyrohyoid membrane distinguished the difficult intubation group from the easy intubation group, with a sensitivity of 96.3% and specificity of 86.4%. For the hyoid bone level, a cut-off value of 0.905 cm (95% CI, 0.706–0.887, AUC, 0.797) had a sensitivity of 74.1% and specificity of 74.4%. Anterior soft tissue thickness from the skin to thyrohyoid membrane was a better predictor of a difficult airway. There was a significant correlation between clinical airway assessments and US airway assessments. Conclusion: Point-of-care US can serve as an independent tool for assessing the airway in intensive care unit (ICU) patients, with anterior soft tissue thickness from skin to thyrohyoid membrane being a superior predictor. Combined models of sonographic and clinical tests could enhance the diagnostic value for identifying difficult intubation cases in ICU patients.

No matching articles

Try another word from the title, author or DOI.

Brief Bio

No bio added yet.

Affiliations

Nothing added yet.

Education

Nothing added yet.

Honors & Awards

Nothing added yet.

Society Memberships

Nothing added yet.

Expertise

Nothing added yet.

Specialty

Nothing added yet.

Other Online Pages

Scholars in the same field

NA
Nalini Aswath
0 publications
SN
Shikha Naagar
0 publications
IH
Imtiyaz Hussain
0 publications
NA
Nirali Alaiya
0 publications
NK
Nithis Kumar S
0 publications
MM
Muxammad Mahramov
JIZZAKH POLYTECHNIC INSTITUTE
0 publications
ZB
Zenish Bhatti
0 publications

Following

Nobody here yet.

Followers

Nobody here yet.

1 Publications

0 Contributions

Nothing added yet.

Filter