PARVATHY NARAYANAN

PARVATHY NARAYANAN

Profile ID RP-003-3223 Joined 2025-05-23 1 article
0Connections
11
Total Views
1
Total Publications
21
Publication Views

Articles(1)

Authors: Parvathy Narayanan, Ravi SV, Elsy P Simon, Chandini Rvaeendran, Sarin Kororth

DOI: 10.18231/j.ijce.2025.019

Volume10
Issue2
Pages109-112
Abstract

Aim and Objectives: Evaluate the fracture behaviour and warning signs (e.g., deformation) of two heat-treated nickel–titanium rotary files—EdgeEndo and TorqueEndo—during repeated simulated clinical use, and determine whether fracture risk differs between them. Introduction: Nickel-titanium (NiTi) rotary endodontic files have revolutionized root canal therapy due to their superior flexibility and shape memory. However, despite advancements in heat treatment technologies that enhance their mechanical properties, these instruments remain susceptible to fracture, especially after repeated clinical use. Understanding the fracture behaviour of heat-treated NiTi files is essential for improving their safety and durability. This in-vitro study aims to assess how multiple uses influence the fracture resistance and failure modes of these instruments under simulated clinical conditions. Materials and Methods: This in-vitro pilot study used 16 extracted maxillary first premolars with ~5° curvature (n = 8 per file type). Each file was used up to 16 times or until fracture, following crown-down preparation, standard irrigation, and sterilization protocol. Files were inspected at 10× magnification after each use for permanent deformation or micro cracks. Fisher’s Exact Test was applied for statistical analysis due to the small sample size (α = 0.05). Results: Edge Endo: 5 fractures; 4 preceded by bending, Torque Endo: 6 fractures; all preceded by deformation. No significant difference in fracture frequency was found (p = 0.64). Warning signs typically appeared after approximately six uses. Conclusion: Both file systems displayed visible warning signs—primarily bending—prior to fracture. No conclusive difference in fracture risk was observed, although this pilot study is limited by size, canal allocation bias, and its in-vitro setup. These findings support further large-scale, randomized studies with microstructural documentation. Keywords: Cyclic fatigue resistance, File separation, Heat treatment, Microstructural analysis

No matching articles

Try another word from the title, author or DOI.

Brief Bio

No bio added yet.

Affiliations

Nothing added yet.

Education

Nothing added yet.

Honors & Awards

Nothing added yet.

Society Memberships

Nothing added yet.

Expertise

Nothing added yet.

Specialty

Nothing added yet.

Other Online Pages

Scholars in the same field

NA
Nirali Alaiya
0 publications
RS
Ritvik Sharma
0 publications
MB
Monika Bharti
0 publications
AD
Agrita Dhyani
Veer chandra singh garhwali government institute of medical science and research
0 publications
SP
Saroj Patidar
0 publications
DN
DEEPTHY NAIR
0 publications
SR
SHUBHRA RAMCHANDANI
0 publications
DV
Deepali Vinay Churi
0 publications

Following

Nobody here yet.

Followers

Nobody here yet.

1 Publications

0 Contributions

Nothing added yet.

Filter