Authors : Kushal Bondade, Eti Ajit, Hemanth K. Kulkarni, Antonio L. Dacosta, Mario Pinto
DOI : 10.18231/2581-4222.2018.0046
Volume : 3
Issue : 4
Year : 0
Page No : 188-192
Introduction: Hemoptysis is a common complaint among patients attending chest clinics. Clinical profile and etiology may vary depending upon patient population studied. Fiber optic bronchoscopy (FOB) is a useful diagnostic tool in such cases to establish accurate diagnosis.
Aim:
Materials and Methods: Institutional based observational prospective study was conducted on 60 patients who presented with hemoptysis to the department of pulmonary medicine at our tertiary care centre. All patients underwent FOB after thorough clinical, radiological and laboratory evaluation.
Results: Mean age of the patients studied was 43.93 ± 13.20 yrs, predominant were male 38(63.3%). Sputum production in 42 patients (70%) was the most common associated symptom followed by dyspnea 34(56.7%) and fever 20(33.3%). On FOB, congestion of the endobronchial lumen was seen in 44 (73.3%), ectasia in 16 (26.6%), bleeding site was localized in 30 (50%) patients. Broncho alveolar lavage (BAL) was positive for Acid fast bacilli in 12 (20%), bacterial culture in 6 (10%) and fungal elements in 2 (3.33%) patients. Endobronchial biopsy (EBB) diagnosed lung malignancy in 10(16.7%) patients.
Conclusion: Bronchiectasis was the most common cause of hemopytsis followed by pulmonary tuberculosis. FOB resulted in diagnosis of three-fourths of the patients analysed in our study with a positive yield of 76.6%.
Keywords: Hemoptysis, Etiological profile, Fiberoptic bronchoscopy (FOB).