Journal article

A Comparative study of conventional external dacryocystorhinostomy with dacryocystorhinostomy using intracystic implant

AMAnup Mondal AMAnup Mondal RARatandeep Kumar Agrawalla RARatandeep Kumar Agrawalla
Year2019
Volume5
Issue3
Pages108-111
Article Details

Abstract

Dacryocystitis is a common manifestation in ophthalmology practice. external DCR is the definitive gold standard management. however many modifications in external DCR are proposed now a days, out of which dcr using intracystic implant is one. This study aiims at comparing the surgical outcome of external conventional DCR with that of DCR using intracystic implant. After a follow up period of 6 months it was observed that the success rate in connventional DCR is significantly better(97%) than DCR using intracystic implant(85%). However intraoperative blood loss and surgical time is significantly less in DCR using intracystic implant than the conventional external DCR.

Keywords: Dacryocystorhinostomy, Intracystic Implant, Syringing, Nldo –Nasolacrimal Duct Obstruction.

Cite this article

Citation data