Comparison of labial frenectomy procedure with conventional surgical technique and diode laser

Authors : Qalbi Fatima, Qalbi Fatima, Aaysha Tabinda Nabi, Aaysha Tabinda Nabi, Md. Tarique Naseem, Md. Tarique Naseem, Kumar Anand, Kumar Anand, Abhishek Verma, Abhishek Verma

DOI : 10.18231/j.ijpi.2020.027

Volume : 5

Issue : 3

Year : 2020

Page No : 120-123

Background : High frenum is very common in function and esthetics. It is manage by procedure such as frenectomy and frenotomy. Most common is the conventional frenectomy which is done by the use of scalpel, now a day’s laser is widely spread and can be used to perform surgeries.
Aim of the study: To compare the degree of postoperative pain experienced by patients during frenectomy procedure with surgical scalpel and diode laser technique.
Materials and Methods: A total of 20 patients with the age range from 16-40 years old had participated in this study, they were all Systemically healthy, nonsmoker and who required labial frenectomy. That were divided into two groups. Group l includes 10 patients in which frenulectomy was done using the diode laser. Group ll with 10 patients in which scalpel had been used to perform conventional frenectomy. Parameters such as pain is evaluated at intervals of 1week, & 1 month.
Results: Intergroup comparison of the mean VAS scores for discomfort and pain for both the groups showed significant difference between the groups. Patients treated with the diode laser had less postoperative pain and required fewer analgesics as compared to patients treated with the conventional scalpel technique.
Conclusion: Based on this study outcome, the diode laser is a dependable alternative as it is an efficient and satisfactory option for procedures like frenectomy.

Keywords: Frenectomy, Surgical Scalpal, Diode Laser.